FAQs
Read through our frequently asked questions below
The Oxford Foot Model code uses the “torsioned” tibia to calculate knee angles (ie taking tibial torsion into account) whilst the Plug-in Gait model uses the “untorsioned” tibia (ie knee rotation is zero in the static trial).